• -20%
Fire Alarm 4 Zone Control Panel
search
  • Fire Alarm 4 Zone Control Panel

Fire Alarm 4 Zone Control Panel

₹9,300
₹7,440 Save 20%
No tax

4 Zone LCD Control panel

Quantity

 

Security policy

 

Delivery policy

 

Return policy

·        CE Approved.

·        16 X 2 Dot Matrix LCD Display.

·        Standby battery backup with built in charging.

·        Switch Mode Power Supply.

·        Tactile Keypad for easy panel operation.

·        System ON indication.

·        Low Battery visual warning with audible tone.

·        Fire / Fault status in unambiguous colored LED indication.

·        2 programmable relays for fire, supervisory and fault.

·        All zones accept smoke detectors and any normally open contact device.

·        Any Zone can be configured as alarm or supervisory.

·        Zone wise isolation and one man walk test facility.

·        Programmable Aux Outputs.

·        Lamp test & Drill test facility.

·        100 All Events log with RTC.

·        Date / Time / Password configuration.

·        Programmable auto silence facility.

·        Zone wise sounder / contact (optional).

·        TCP-IP / GSM facility (optional).

·        All field wiring circuits are supervised.    

Primary Power
120 / 230VAC + 10% -15%, 60 / 50 Hz, 50W

Standby Power
24VDC (2 Nos of 12V, 3.5Ah Sealed Lead acid battery)
Quiescent current   :   55mA

Operating Condition
Operating Temperature 0 – 49° C / 32 – 120° F.
Storage Temperature 0 – 60° C
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ± 2° C / 90 ± 3° F

Quiescent Current
2 Zone
4 zone

40mA
50mA

Charging Circuit
Charging voltage
Charging current

28 V ± 5%
350mA (max)

24VDC
Quantity
Voltage
Current

1 No
24VDC continuous or resettable (Regulated)
100mA (max)

Notification Appliance Circuits
Wiring style
Quantity
Operating voltage
Current
EOL resistor

Class B
1 No
24VDC (Regulated)
350mA
4K7, 1/2 watt

Relays
Type
Quantity
Relay contact rating
Power factor

Form C
2 No’s (Programmable)
1A @ 30 VDC
1.0

Initiating Device Circuits
Wiring style
Quantity
Normal operating voltage
Alarm current
Short circuit current
Loop resistance
EOL Resistor
Standby Current

Class B
2 or 4 (102R- 104R)
14 – 21 VDC
15 – 35 mA
42 mA (max)
50 Ω (max)
4K7, ½ watt
6.8 mA (2.4 mA for detectors)

RS 485
Nodes
Wiring Style
Wire type
Circuit Length
Loop resistance

1
Class B
Twisted pair
1.2 Km (Max)
100 Ohms

Dimensions

:

300L X 200W X 95D

Wire Size

:

1.5 Sq mm

IP rating

:

IP 60

Color

:

Black

Material

:

FRABS plastic

Cable Entry

:

11 x ø19mm Knockout on top of the cabinet

Ravel
RE-104R
Comments (0)
No customer reviews for the moment.