• -30%
Mounting Base
search
  • Mounting Base

Mounting Base

₹300
₹210 Save 30%
No tax

A common base for both GST addressable and conventional DI/DC series detector, provides mechanical fixing and electrical connection. There is no electrical component on the base.

The DB-01 base has 4 terminals marked with 1-4. For the detail connections, please refer to the manual of installed detector.

Quantity

In the world of fire safety, reliable and efficient equipment is paramount. Among the myriad of components that make up a robust fire alarm system, the GST Mounting Base plays a crucial role. Designed to support various detectors, the GST Mounting Base ensures that the fire alarm system functions optimally, providing early warning and safeguarding lives and property. This article delves into the specifics of the GST Mounting Base, its compatibility with different devices, material composition, and dimensions, highlighting why it is an indispensable element in modern fire alarm systems.

Overview of GST Mounting Bases

The GST Mounting Base is an integral part of fire detection systems, providing a secure platform for detectors. These bases are designed to be compatible with a range of detectors from the GST series, ensuring flexibility and ease of installation. The mounting base serves as the connection point between the detector and the building's electrical system, facilitating communication and power supply.

Key Features and Specifications

Compatible Devices

One of the significant advantages of the GST Mounting Base is its compatibility with various devices. This compatibility ensures that the base can be used with multiple detector models, making it a versatile choice for different fire detection setups. The compatible devices include:

  • DI-9101E
  • DI-9102E

  • DI-9103E

  • DC-9101E

  • DC-9102E

  • DC-9103E

  • DI-9405

  • DI-9406

Each of these models represents a different type of detector, ranging from smoke detectors to heat detectors, ensuring comprehensive coverage of different fire detection needs.

Material Composition

The GST Mounting Base is made from Acrylonitrile Butadiene Styrene (ABS), a high-quality thermoplastic polymer known for its robustness and durability. ABS is widely used in various industries due to its excellent properties, such as high impact resistance, good electrical insulation, and ease of fabrication.

The choice of ABS for the GST Mounting Base ensures that it can withstand the rigors of installation and use in various environments. ABS is also resistant to heat and fire, adding an extra layer of safety to the fire detection system. Its durability ensures that the mounting base remains reliable over long periods, reducing the need for frequent replacements.

Dimensions

The dimensions of the GST Mounting Base are carefully designed to ensure a perfect fit for the compatible detectors while being compact enough to be unobtrusive. The base measures 100mm in diameter and 14mm in height. These dimensions provide a sturdy and stable platform for the detectors while ensuring that the base can be easily installed in various locations, including ceilings and walls.

Importance of the GST Mounting Base in Fire Alarm Systems

The GST Mounting Base is more than just a physical support for detectors; it plays a crucial role in the overall functionality and reliability of fire alarm systems. Here are some reasons why the GST Mounting Base is essential:

1. Ensuring Proper Detector Alignment

The mounting base ensures that detectors are correctly aligned and positioned for optimal performance. Proper alignment is crucial for the accurate detection of smoke or heat, allowing the system to respond quickly in case of a fire.

2. Secure and Stable Installation

The GST Mounting Base provides a secure and stable installation point for detectors. This stability is essential to prevent false alarms caused by vibrations or movements and to ensure that the detectors remain in place during emergencies.

3. Facilitating Easy Maintenance and Replacement

With a standardized mounting base, maintenance and replacement of detectors become more straightforward. Technicians can quickly remove and replace detectors without needing to alter the mounting base, saving time and reducing downtime of the fire alarm system.

4. Enhancing System Aesthetics

The sleek and compact design of the GST Mounting Base ensures that it blends seamlessly with the building's interior. This aesthetic consideration is important in modern buildings where the visual appeal of safety equipment is also a factor.

Installation and Maintenance

Installation Process

Installing the GST Mounting Base is a straightforward process that requires minimal tools and expertise. The base is typically mounted onto the ceiling or wall using screws, ensuring a secure attachment. Once the base is in place, the compatible detector can be easily snapped into position, completing the installation.

Maintenance Considerations

Regular maintenance of the GST Mounting Base and the attached detectors is crucial to ensure the fire alarm system remains functional. Maintenance tasks include:

Visual Inspection: Regularly checking the mounting base and detectors for any signs of damage or wear.

Cleaning: Ensuring that the detectors and mounting base are free from dust and debris that could interfere with their operation.

Testing: Periodically testing the detectors to ensure they are functioning correctly and that the mounting base is providing a stable connection.

Advantages of Using the GST Mounting Base

The GST Mounting Base offers several advantages that make it a preferred choice for fire alarm systems:

1. Versatility

With compatibility across a range of detector models, the GST Mounting Base offers versatility in designing and upgrading fire alarm systems. This compatibility allows for easy integration of different types of detectors to meet specific safety requirements.

2. Durability

The use of ABS material ensures that the mounting base is durable and long-lasting. This durability translates to lower maintenance costs and fewer replacements, providing a cost-effective solution for building safety.

3. Ease of Installation

The straightforward installation process of the GST Mounting Base reduces the time and effort required to set up a fire alarm system. This ease of installation is particularly beneficial in large buildings where multiple detectors need to be installed.

4. Reliability

The robust design and high-quality materials used in the GST Mounting Base ensure reliable performance. This reliability is crucial for fire alarm systems, where any failure can have severe consequences.