• -23.09%
Addressable Manual call point
search
  • Addressable Manual call point

Addressable Manual call point

₹4,525
₹3,480 Save 23.09%
No tax

Connecting to the loop of GST fire alarm system, DI-9204E Digital Manual Call Point (MCP) is suitable for public places. When there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound.

Quantity

Fire safety is a critical component of building management, and modern technology has significantly enhanced the effectiveness and reliability of fire detection and alarm systems. One such technological advancement is the GST Addressable Manual Call Point (MCP), a device designed to provide a reliable and efficient means of manually triggering an alarm in the event of a fire. This article delves into the features, benefits, and standards associated with the GST Addressable MCP, highlighting its importance in contemporary fire safety systems.

Features of GST Addressable Manual Call Point

The GST Addressable Manual Call Point is distinguished by several key features that enhance its functionality and reliability:

Electronically Addressed: Each GST Addressable MCP is electronically addressed, allowing for unique identification within the fire alarm system. This addressing capability ensures that the exact location of the triggered MCP can be quickly identified, facilitating rapid response and minimizing the risk of damage or injury. The address of each MCP can be modified in the field, providing flexibility and ease of installation.

Alarm Activation and Reset: The MCP is designed to be activated by pressing a designated button, which initiates the alarm. This straightforward method ensures that individuals can quickly and easily trigger the alarm in an emergency. To reset the MCP after an activation, a special key is required. This feature prevents unauthorized resetting of the device, ensuring that the alarm system maintains its integrity and reliability.

Plug-in Structure: The plug-in structure of the GST Addressable MCP simplifies installation and maintenance. This design allows the MCP to be easily connected and disconnected from the system, reducing downtime and ensuring that the device can be quickly replaced or serviced if necessary.

Compliance with Standards: The GST Addressable MCP conforms to EN 54-11, a European standard that specifies requirements for manual call points used in fire detection and fire alarm systems. Compliance with this standard ensures that the MCP meets rigorous safety, performance, and reliability criteria, making it a trusted component of any fire alarm system.

Benefits of GST Addressable Manual Call Point

The GST Addressable MCP offers several benefits that make it an essential part of modern fire alarm systems:

Enhanced Safety: By providing a reliable means of manually triggering an alarm, the GST Addressable MCP enhances overall safety within a building. In the event of a fire, occupants can quickly activate the alarm, ensuring that everyone is alerted to the danger and can evacuate promptly.

Accurate Location Identification: The electronic addressing feature of the MCP allows for precise identification of the activated device. This accuracy is crucial for first responders, enabling them to quickly locate the source of the alarm and address the fire more effectively.

Ease of Installation and Maintenance: The plug-in structure of the MCP makes it easy to install and maintain. This design reduces the time and effort required for installation, ensuring that the fire alarm system can be set up quickly and efficiently. Additionally, the ability to modify the address in the field adds to the flexibility and convenience of the device.

Compliance with International Standards: Adherence to EN 54-11 ensures that the GST Addressable MCP meets international standards for performance and reliability. This compliance provides peace of mind for building owners and managers, knowing that the MCP is a high-quality, dependable component of their fire safety system.

Understanding EN 54-11 Standard

The EN 54-11 standard is a critical benchmark for manual call points used in fire detection and alarm systems. It specifies the requirements and test methods for MCPs to ensure they perform reliably in the event of a fire. Key aspects of the EN 54-11 standard include:

Durability: MCPs must be designed to withstand the environmental conditions in which they will be used, including factors such as temperature, humidity, and physical impact.

Performance: MCPs must reliably trigger an alarm when activated, with consistent performance over time. The standard includes tests to verify the responsiveness and reliability of the device.

Safety: MCPs must be safe to use, with features that prevent accidental activation and unauthorized resetting. The inclusion of a special key for resetting the GST Addressable MCP ensures compliance with this aspect of the standard.

Installation and Use of GST Addressable MCP

Proper installation and use of the GST Addressable MCP are crucial for ensuring the effectiveness of the fire alarm system. The following steps outline the key considerations for installing and using the MCP:

Site Survey and Planning: Before installation, conduct a thorough site survey to determine the optimal locations for the MCPs. Consider areas with high occupancy, exit routes, and potential fire hazards.

Address Configuration: Configure the electronic address of each MCP according to the fire alarm system design. Ensure that the addresses are unique and correspond to the planned locations.

Installation: Install the MCPs using the plug-in structure, ensuring that each device is securely connected to the system. Follow the manufacturer’s guidelines for mounting height and placement to ensure accessibility and visibility.

Testing and Commissioning: After installation, test each MCP to verify its functionality and ensure that it communicates correctly with the fire alarm control panel. Conduct regular testing as part of the fire alarm system’s maintenance schedule.

Training: Provide training for building occupants and staff on the proper use of the MCPs. Ensure that everyone knows how to activate the MCP in an emergency and understands the importance of not tampering with the devices.

Integration with Fire Alarm Systems

The GST Addressable MCP is designed to integrate seamlessly with GST’s range of fire alarm control panels and other detection devices. This integration enhances the overall functionality and responsiveness of the fire alarm system. Key aspects of integration include:

System Communication: The electronically addressed MCPs communicate with the fire alarm control panel, providing real-time information about the status and location of each device. This communication ensures that the control panel can quickly identify and respond to an alarm activation.

Networked Solutions: In larger buildings or complex facilities, the GST Addressable MCP can be part of a networked fire alarm system. This setup allows multiple MCPs and other detection devices to be interconnected, providing comprehensive coverage and centralized monitoring.

Compatibility: The GST Addressable MCP is compatible with a wide range of detection devices, including smoke detectors, heat detectors, and other manual call points. This compatibility ensures that the MCP can be integrated into existing fire alarm systems without the need for extensive modifications.

Maintenance and Troubleshooting

Regular maintenance and troubleshooting are essential for ensuring the continued reliability of the GST Addressable MCP. Key maintenance activities include:

Routine Inspections: Conduct regular visual inspections of the MCPs to check for signs of damage or tampering. Ensure that the devices are clean and free from obstructions.

Functional Testing: Perform regular functional tests to verify that the MCPs are working correctly. This testing should include pressing the activation button and verifying that the alarm is triggered and communicated to the control panel.

Address Verification: Periodically check the electronic addresses of the MCPs to ensure they are correctly configured and correspond to the planned locations. Update the addresses as needed to reflect any changes in the building layout or fire alarm system design.

Key Management: Ensure that the special keys required for resetting the MCPs are securely stored and accessible only to authorized personnel. This management prevents unauthorized resetting and maintains the integrity of the fire alarm system.

GST
DI-9204E
Comments (0)
No customer reviews for the moment.